Assigned certifier: who to appoint and what to agree
Choose an assigned certifier for your Irish self-build: eligible professions, inspection plans, fees, records and what to agree before work starts.
Stage 5: Notify Building Control
Does a self-build house need a fire safety certificate or disability access certificate? What the regulations exempt, and what Parts B and M still require.
A new house, used as a dwelling other than a flat, does not need a fire safety certificate or a disability access certificate. You still need to meet Part B (Fire Safety) and Part M (Access and Use) of the Building Regulations.
Ask your designer to confirm the classification before relying on either exemption. A flat, granny flat or commercial element can change the answer. Agree the design, inspections and records with your designer and building control authority before construction starts.
Part III of the Building Control Regulations 1997 (S.I. 496 of 1997) requires a fire safety certificate for works and buildings to which Part B of the Building Regulations applies, with a list of exemptions. Article 11(2) lists them. Those relevant to a self-builder are:
The exemption also covers works in connection with such a building, provided the building remains one of those types afterwards.
The exemption removes the separate certificate application. Your design and construction still have to comply with Part B. Agree who will check concealed fire-safety details, when they will inspect them and what records they will keep before the work is covered.
If your project has any of these features, ask building control early. A fire safety certificate application has its own fee, drawings and processing time, and cannot be bolted on at the end.
A single dwelling house exempt from the fire safety certificate requirement is also exempt from the disability access certificate requirement. Part M still applies to the house. You need to design and build for access and use even though there is no separate certificate application.
The link between the two certificate requirements is in Article 20D of Part IIIB, introduced by the Building Control (Amendment) Regulations 2009 (S.I. 351/2009). It covers the works and buildings to which Part III applies under the listed paragraphs of Article 11(1). Ask building control to confirm the scope if your project includes anything beyond the single house.
For dwelling houses, S.I. 57/2017 introduced requirements B6–B10 and the B11 definition of a dwelling house as a dwelling other than a flat. The following is a practical summary, not a specification:
| Part | Discuss with your designer |
|---|---|
| B6 Warning and escape | Early fire warning, escape routes, bedroom escape arrangements and protected stairs where required |
| B7 Internal linings | Appropriate wall and ceiling lining performance |
| B8 Structure | Stability in fire, separation from adjoining buildings, fire-resisting subdivisions and concealed fire/smoke spread |
| B9 External spread | External walls, roof coverings and separation from neighbouring buildings |
| B10 Fire-service access | Access for appliances and facilities needed by the fire service |
Use Technical Guidance Document B (Dwelling Houses) for detailed solutions for typical houses. Following the relevant Technical Guidance Document (TGD) is evidence of compliance; suitable alternative approaches are possible. Ask your designer which edition and transitional provisions apply.
Agree who checks the construction and records the evidence. Put checks for fire stopping around service penetrations and cavity barriers into the inspection plan before the work is covered. These are hold points: stages when work must remain visible until the agreed check is done. See assigned certifier explained.
Tip
Timber frame, modular and rural houses each add specific fire questions: cavity barriers and fire stopping in timber frame, the access lane length for rural sites, and any internal garage. Ask your designer which of these apply to your house and where they appear in the drawings and specification. For the insurance side, see self-build insurance.
The current Part M was substituted by S.I. 608/2022, which took effect on 1 January 2023 subject to transitional provisions and revoked the 2010 amendment. It requires adequate provision for access and use. It also includes a changing-places toilet requirement that depends on building use and size; ask your designer which provisions apply to your project.
Part M does not apply to extensions to and material alterations of existing dwellings where the works do not create a new dwelling.
For your new self-build house, Part M applies. Technical Guidance Document M covers the route from the boundary to the entrance, entrances and thresholds, circulation space and doors, a toilet on the entrance level, and other dwelling provisions. Plan these features on the first drawings to avoid costly alterations later:
Check these details before approving the layout, entrance levels or external works. A doorway or approach that needs changing later can affect several trades.
A single dwelling on a single-unit development can opt out of statutory certification by submitting the prescribed declaration with its commencement notice under S.I. 365/2015. Building Regulations still apply, and the owner still needs competent design, construction and appropriate evidence of compliance. Agree inspection and record-keeping arrangements before choosing this route.
Where the statutory certification route is used:
Confirm separately what evidence your lender, insurer and warranty provider require, including whether they accept an opt-out project. The Building Control Act 1990 gives building control authorities powers to inspect and to take enforcement action where the regulations are breached, whether or not a certificate was required. See building regulations for self-builds.
For where this sits in the overall programme, see the stages of a self-build.
No. Article 11(2)(b) of the Building Control Regulations 1997 exempts a building used as a dwelling, other than a flat, from the fire safety certificate requirement. Flats, apartments and some mixed-use buildings are different.
No. The disability access certificate is required for the works and buildings to which the fire safety certificate requirement applies, and a single dwelling house is exempt from that.
Yes. Exemption from the certificate does not exempt the building from the Building Regulations. Part B (fire) and Part M (access and use) still apply. Statutory certification is one route; an eligible single dwelling can opt out, without removing the duty to comply.
A single-storey domestic garage and certain single-storey ancillary garden buildings are exempt from the fire safety certificate. A separate flat, or an attached unit that is a flat rather than a dwelling, can bring the certificate requirement back, so ask building control before you design it.
In the Technical Guidance Documents B (Fire Safety) and M (Access and Use), published by the Department. Your designer checks the applicable regulations, guidance edition and transitional provisions.
Last reviewed 19 October 2026. Rules and figures change, so confirm anything important with the source before you rely on it.